Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
  Name SKU Description Category
DKK-TOA RC-37P ● Measures diluted sodium hypochloric acid concentration without reagent ●Polishing beads cleaning method allows for stable measurement ●Waterproof design (IP67: 1m depth, up to 30mins)   Meas. range 20 - 300mg/L 5 - 40℃ Handheld Hypochlorite Concentration Meter
DKK-TOA OZ-21P Simple, reagentless measurement of concentration of ozone stream water produced by ozone water generator Waterproof design (IP67: 1m depth, up to 30mins) Polishing beads cleaning method allows for stable measurement External printer connectable Meas. range 0 - 2.00 mg/L 5 - 40℃ Portable Dissolved Ozone Meter
DKK-TOA OZ-20 / 30 ●Portable, easy calibration, continuous measurement capability ●Two types available: OZ-20(for liquid phase) and OZ-30(for gas phase) ●Easy measurement, simply by placing electrode in the atmosphere ●AC/DC 2-way power source ●Optional flow cell for dissolved ozone Meas. range 1.5 - 19.99mg/L(for liquid), 1 - 100g/m3 (for air) Portable Ozone Meter
DKK-TOA DH-35A ●Fast response with membrane polarographic electrode ●Highly sensitive measurement at μg/L level ●Atmospheric calibration method and hydrogen standard gas not required ●AC/DC batteries 2-way power supply ●Equipped with flow cell and analogue output cable Meas. range 0.0ppb - 10.00ppm Portable Dissolved Hydrogen Meter
DKK-TOA CGP-31 Enables measurement of CO2 in both liquid phase and gas phase Wide measurement range(0.1 - 100%) Membrane electrode allows for reliable measurement Power-saving design; rechargeable battery adaptable Waterproof design(IP67: 1m depth, up to 30mins) Meas. range Liquid phase: 1.49 - 1490 mg/L Gas phase: 0.1 - 100% Portable Carbon Dioxide Meter
DKK-TOA MDM-25A(Including a PVC Sensor) Concentration of acid and alkali measurable High concentration range measurable by electromagnetic method Analog output enables easy continuous measurement Switchable concentration and conductivity rate Easy maintenance requires no daily calibration Meas. range (conductivity rate) 0 - 200 S/m Portable Electromagnetic Meter
DKK-TOA SSM-21P Handheld Surface Salinity Meter SSM-21P Compliant with PSPC  Ideal for surface salinity measurements of paints used in ship coatings  Simple operation (just attach the cell to the meter and inject pure water into the cell)   Measurement range 0 - 199.9mg/m2, 0 - 1999mg/m2 0 - 199.9μS/cm, 0 - 1.999mS/cm 0 - 50℃ Automated Soluble Salt Meter for IMO PSPC (ISO 16145-4) Portable Surface Salinity Meter
DKK-TOA WDM-135A (2-wire) / WDM-136A (4-wire) Industrial Conductivity Transmitter WDM-135A (2-wire) / WDM-136A (4-wire) Easy-to-use conductivity analyzer for field installation in a compact and rigid aluminum enclosure Wide application range from ultra-pure water to wastewater  Alterable output range Meas. range Minimum: 0 - 0.2 μS/cm Maximum: 0 - 20 mS/cm Transmitter for Industrial Conductivity Analyzer
DKK-TOA WBM-160 (4-wire) Industrial Conductivity Transmitter WBM-160 (4-wire) Multi-function conductivity analyzer for field installation in a compact aluminum diecast enclosure Wide application range from ultrapure water to wastewater 2-point contact signal, 2-channel output including temperature (RS-232 optional) Power supply: AC90 - 264V, 50/60Hz   Meas. range Minimum : 0 - 0.2 μS/cm Maximum : 0 - 20 mS/cm Transmitter for Industrial Conductivity Analyzer
DKK-TOA WBM-165H (2-wire) Conductivity Transmitter with HART Interface WBM-165H (2-wire) HART communication protocol interface with a 2-wire, 24 VDC circuit Aluminum diecast enclosure, digital display and a wide range of other useful features One-touch auto calibration Self-diagnostic function Meas. range Minimum : 0 - 0.2 μS/cm Maximum : 0 - 20 mS/cm Transmitter for Industrial Conductivity Analyzer
DKK-TOA WBM-100 Compact DIN 96 size Temperature compensation computed by a microcomputer  Cell constant value adjustable depends on customers' need Water temperature displayable Power supply: AC90 - 264V, 50/60Hz Meas. range Minimum : 0 - 0.2 μS/cm Maximum : 0 - 20 mS/cm Panel Type Conductivity Analyzer
DKK-TOA WBM-210A Compact DIN 96 size Conductivity meter with built-in microcomputer for various applications such as ultra-pure water production, boiler plants, foodstuff plants, etc. Two detectors connectable  RS-232 equipped as standard specification Output: 2-channel, insulated, 4 - 20mA Meas. range Minimum : 0 - 0.2 μS/cm Maximum: 0 - 20 mS/cm Panel Type Conductivity Analyzer
DKK-TOA WBM-121A / AK Cell Sanitary Type Conductivity Analyzer/Detector WBM-121A / AK Cell Compact DIN 96 size Designed for sanitary conductivity analyzer for the food industry Applied in foodstuff plants and installed in pipes and tanks. Best suited for CIP (stationary cleaning) management, debubbling agent control and liquid level management Meas. range 0 - 300/3000 μS/cm (at 25 degrees C) 0 - 20/200 mS/cm (at 25 degrees C) Panel Type Conductivity Analyzer
DKK-TOA AA-1(for Standard) / AA-2 (for Ultrapure Water) Single-function (no indication) conductivity analyzer for field installation Easy installation for the one-unit amplifier and detector Output: 4 - 20mADC Power supply: 100VAC  Meas. range AA-1: 0 - 2 μS/cm to 0 - 10000 μS/cm AA-2: 0 - 0.2/0.5/1.0 μS/cm Conductivity Detectors with Amplifier
DKK-TOA A5/A6 Series Hermetically sealed 2-electrode type detector featured with excellent heat-proofing and pressure tightness Pipeline-insertion/immersion/flow-through/throw-in/leadless, etc. type available Four types of cell constants available: 0.01, 0.1, 1.0, 10 cm-1 Meas. range Minimum : 0 - 0.2 μS/cm Maximum : 0 - 20 mS/cm Industrial Conductivity Detector
DKK-TOA AR4/AR5 Series Compact 2-electrode type (titanium) detector designed for ultrapure water Pipeline insertion type, leadless type Two types of cell constants available: 0.01, 0.1 cm-1 Meas. range 0 - 20/200 MΩ·cm 0 - 0.2/2 μS/cm Industrial Conductivity Detector
DKK-TOA AQM-100A Resistivity Analyzer for Ultra-Pure Water AQM-100A Compact DIN 96 size Best suited for water quality control in ultra-pure water production lines  Two detectors connectable Meas. range 0.00 - 20.00 MΩ・cm Panel Type Resistivity Analyzer for Ultra-Pure Water
DKK-TOA AQM-210A Panel Type Resistivity Analyzer AQM-210A Compact DIN 96 size Best suited for water quality control in ultra-pure water production lines  Two detectors connectable RS-232 equipped as standard specification Output: 2-channel, insulated, 4 - 20mA Meas. range 0.00 - 20.00 MΩ・cm Panel Type Resistivity Analyzer for Ultra-Pure Water
DKK-TOA MDM-135A (2-wire) Electromagnetic Conductivity Transmitter MDM-135A (2-wire) Electromagnetic conductivity analyzer for field installation in a compact and rigid aluminum enclosure  Made for accurate measurements for high conductivity corrosive solutions (such as strong acid/alkali) Alterable output range Meas. range Minimum : 0 - 2 mS/cm Maximum : 0 - 2000 mS/cm Transmitter for Electromagnetic Conductivity Analyzer
DKK-TOA MDM-137A (2-wire) Electromagnetic Concentration Transmitter MDM-137A (2-wire) Electromagnetic concentration analyzer for field installation in a compact and rigid aluminum enclosure   Conductivity of NaCl, HCl, H2SO4, etc. are measured and converted to concentration (%)data automatically Assignable measurement range Examples of measurement ranges NaCl: 0 - 10% HCl: 30 - 40% H2SO4: 93 - 99.5% NaOH: 0 - 15% Transmitter for Electromagnetic Conductivity Analyzer