Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
  Name SKU Description Category
Kyoritsu 2413R Large transformer jaws of 68mm diameter makes it possible to clamp on all three or four wires (3 phases) together for leakage current measurement. • True RMS enables an accurate measurement for distorted waveforms. • Measurement from mA up toAC 1000A • Frequency filter switch to eliminate the effect of the harmonics. • 2 way analogue output terminal:AC current detected by transformer jaws is converted to AC and DC voltage. Output cord model 7073 (option) is... Leakage Clamp Meters
Kyoritsu 2431 Frequency Selector Switch to eliminate the effect of harmonics. • Three AC current ranges 20mA/200mA/200A. • Rotary switch for easy one finger power-on and range selection. Leakage Clamp Meters
Kyoritsu 2432 High Sensitive Model • Frequency Selector Switch to eliminate the effect of harmonics. • Three AC current ranges : 4mA/40mA/100A Leakage Clamp Meters
Kyoritsu 2433 Frequency Selector Switch to eliminate the effect of harmonics. • Three AC current ranges : 40mA/400mA/400A. Leakage Clamp Meters
Kyoritsu 2433R Frequency Selector Switch to eliminate the effect of harmonics. • Three AC current ranges: 40mA/400mA/400A. Leakage Clamp Meters
Kyoritsu 2434 Least affected by external stray magnetic field. • 20mA AC max. in proximity to a 15mm-dia conductor carrying 100A AC • Frequency Selector Switch to eliminate the effect of harmonics. Leakage Clamp Meters
Kyoritsu 5010 (for Current) / 5020 (for Current & Voltage) 3 channel inputs for the simultaneous recording of Leakage Current, Load Current and Voltage • Power Quality analysis(only on KEW 5020)(Power Quality:Reference voltage, Swell, Dip, Short power Interruptions)   Large Capacity for storing 60,000 data points 60,000 data points can be recorded when 1ch is used, and when all the three channels are used, 20,000 data points per channel can be recorded   Lowpass Filter will filter out the... Logger
Kyoritsu 5001 THE LEAKAGE CURRENT IS RECORDED BY 3CH INPUT60,000 DATA IS RECORDED 60,000 data is recorded when 1ch is used and when three all channels are used, 20,000 data is recorded for each channel Continuous measurement time   About 40 days   Data where it doesn’t disappear even if battery is consumed   Data doesn’t disappear by using the nonvolatile memory when the battery is consumed and the battery is exchanged.... Logger
Kyoritsu 8309 Floating voltage can be measured *Floating voltage:phase to phase voltage not grounded *KEW 5020-01:KEW 5020 logger with KEW 8309 (1 pce.) For use with following model 5020 Voltage Sensor
Kyoritsu 8130 Can measure AC current up to 1000A • Flexible and light weight by the air core coil used at the sensor part • Designed to meet the international safety standardIEC 61010-1 CAT IV 300V, CAT III 600V Applicable model 5010/5020 (*), 6300, 6305, 6310, 6315 Flexible Clamp Sensor
Kyoritsu 8129 Flexible for various test fields • Can measure AC current up to 3000A • Flexible and light weight by the air core coil used at the sensor part • Measurable conductor size:max Φ150mm • Designed to meet the international safety standardIEC 61010-1 CAT.III 600V Applicable model 5010/5020 (*), 6300, 6305, 6310, 6315 Flexible Clamp Sensor
Kyoritsu 8121 Applicable model 5010/5020 Conductor size Φ24 Rated current AC 100A Output voltage AC 500mV/100A (AC 5mV/A) Accuracy |±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz) Withstand voltage AC 3540V for 5 seconds Cable length Approx. 2m Output connector MINI DIN 6pin Operating temperature ranges 0~40ºC, less than 85% RH (without condensation) Output impedance Approx. 9.5Ω Applicable standards IEC 61010-1:2001,IEC... Load current clamp sensors
Kyoritsu 8122 Applicable model 5010/5020 Conductor size Φ40 Rated current AC 500A Output voltage AC 500mV/500A (AC 1mV/A) Accuracy |±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz) Withstand voltage AC 5350V for 5 seconds Cable length Approx. 2m Output connector MINI DIN 6pin Operating temperature ranges 0~40ºC, less than 85% RH (without condensation) Output impedance Approx. 1.9Ω Applicable standards IEC 61010-1:2001,IEC... Load current clamp sensors
Kyoritsu 8123 Applicable model 5010/5020 Conductor size Φ55 Rated current AC 1000A Output voltage AC 500mV/1000A (AC 0.5mV/A) Accuracy |±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz) Withstand voltage AC 5350V for 5 seconds Cable length Approx. 2m Output connector MINI DIN 6pin Operating temperature ranges 0~40ºC, less than 85% RH (without condensation) Output impedance Approx. 1.5Ω Applicable standards IEC 61010-1:2001,IEC... Load current clamp sensors
Kyoritsu 8146 Applicable model 5010/5020, 6310, 6315 * Cannot be used for power measurement. Conductor size Φ24 Rated current AC 30A Output voltage AC 1500mV/30A (AC 50mV/A) Accuracy 0~15A|±1.0%rdg±0.1mV (50/60Hz)|±2.0%rdg±0.2mV (40Hz~1kHz) 15~30A|±5.0%rdg (50/60Hz)|±10.0%rdg (45Hz~1kHz) Withstand voltage AC 3540V for 5 seconds Cable length Approx. 2m Output connector MINI DIN 6pin Operating temperature ranges 0~50ºC, less than... Leakage & Load current clamp sensors
Kyoritsu 8147 Applicable model 5010/5020, 6310, 6315 * Cannot be used for power measurement. Leakage & Load current clamp sensors
Kyoritsu 8148 Applicable model 5010/5020, 6310, 6315 * Cannot be used for power measurement. Leakage & Load current clamp sensors
Kyoritsu 8141 Applicable model 5000/5001, 5010/5020, 6310 * Cannot be used for power measurement. Leakage current clamp sensors
Kyoritsu 8142 Applicable model 5000/5001, 5010/5020, 6310 * Cannot be used for power measurement. Leakage current clamp sensors
Kyoritsu 8143 Applicable model 5000/5001, 5010/5020, 6310 * Cannot be used for power measurement. Leakage current clamp sensors